Back
  • Sensor MPE DIP Switches

    DIPs 1,2,3 set rack size / type

    Configured as:

    DIP1

    DIP2

    DIP3

    SR6 3x12k

    Off

    Off

    Off

    SR6 6x6k

    Off

    Off

    On

    SR6 12x2k

    Off

    On 

    Off

    SR12  6x12k bal.

    Off

    On

    On

    SR12  12x6k bal. 

    On

    Off 

    Off

    SR12  24x2k bal.

    On 

    Off

    On

    SR12  24x2k

    On

    On

    Off



    DIP 4 Selects Multiplexing - On sets whole rack for MUX.
    (See Article S5Q-W1M-NMQR - How Do I Set Up Dimmer Doubling on the Sensor MPE) for more information.

    DIP 5 Selects Input Filter for AMX - On enables input filtering

    DIPs 6,7,8 set input options (AMX and Analog not available on DMX-Only MPE)

    6 On enables 0-10v analog
    7 On enables AMX 192
    8 On enables DMX 512

    NOTE:  AMX and Analog cannot be enabled at the same time!  Enabling AMX disables Analog.

    NOTE:  Newer MPEs do not support AMX or Analog.  If the MPE says "DMX512" on the front, it only supports DMX512.