  • S P E C I F I C A T I O N S
    FEATURES
    • Wired-DMX or wireless ArcMesh control network (via ArcMesh D1/D4 Driver)
    • Stepless, smooth dimming to absolute zero
    • Convection cooled
    • Fan-free, silent operation
    • Black or white color options
    • Available in a dual-input emergency version (via D1/D4 Driver)
    OPTICAL
    • High-grade, narrowly binned Bridgelux emitters
    • CRI (color rendering index) = 90+
    • 2700K/3000K color-temperature options
    • 24°, 33° and 50° beam-angle options
    • Excellent thermal management ensures the LEDs will meet anticipated 50,000-hour life cycle
    • 628 lumen output
    • Recessed reflectors for minimal glare
    ELECTRICAL
    • Requires separate D1/D4 Driver
    • 10W emitter allows two MR16 luminaires can be run from a single D1 Driver using an optional Y-split adaptor
    • Less than 1W quiescent load
    • High-frequency dimming control
    • Four-pin Molex connections

    PHYSICAL
    Product Dimensions* Product Weight
    MODEL HEIGHT WIDTH DEPTH
    inches mm inches mm inches mm
    Decor MR16 Recessed 2.76 70 2.75      
    Decor MR16 Yoke-Mount 2.76 70 1.98      
    MODEL WEIGHT SHIPPING WEIGHT
    lbs kgs lbs kgs
    Decor MR16 Recessed 0.4  
    Decor MR16 Yoke-Mount 0.4  

    Decor MR16 recessed version
    Decor MR16 recessed version

    Decor MR16 yoke-mount version
    Decor MR16 yoke-mount version

    Decor MR16 connections
    Decor MR16 connections

    Lumen table
    COLOR TEMP CRI MR16 IM @ 70ͦ C ONE-CELL IM @ 70ͦ C TWO-CELL IM @ 70ͦ C FOUR-CELL IM @ 70ͦ C EIGHT-CELL IM @ 70ͦ C
    2700K 90 572 1191.8 2383.6 4767.5 9534.4
    3000K 90 628 1280.3 2560.6 5121.2 10242.4

    TYPICAL SYSTEM LAYOUT

    ArcSystem luminaires require a constant circuit connection for operation. Intensity control of each luminaire is achieved by using either a wired DMX signal (via RJ45) or a wireless ArcMesh signal (via ArcMesh Transmitter).

    System Layout

    EMERGENCY CONNECTION

    A dual-input emergency version of this luminaire is available. Emergency luminaires have two line voltage leads that are wired to the luminaire and have the following functions:

    • Normal power
    • Emergency power (hot, neutral and earth)

    Note: Input 2 (emergency power) must be wired in fire-rated cable to the luminaire connection point. Please consult with a qualified electrical engineer for correct installation procedures.

    Emergency Connection

    If normal power has been lost, the luminaire will be forced into a full-on state running from the emergency power supply. There is no control of the luminaire via wireless ArcMesh network or wired DMX until normal power is turned back on.